mirror of
https://git.hardenedbsd.org/hardenedbsd/HardenedBSD.git
synced 2024-12-28 14:24:09 +01:00
Fix the fallouts from r146267:
- Add the forgotten "mode" argument to the "mode" command. - Move the description of "info" to where it belongs.
This commit is contained in:
parent
0f3311c56f
commit
a794372087
Notes:
svn2git
2020-12-20 02:59:44 +00:00
svn path=/head/; revision=186079
@ -25,7 +25,7 @@
|
||||
.\"
|
||||
.\" $FreeBSD$
|
||||
.\"
|
||||
.Dd June 25, 2008
|
||||
.Dd December 14, 2008
|
||||
.Dt ATACONTROL 8
|
||||
.Os
|
||||
.Sh NAME
|
||||
@ -63,6 +63,7 @@
|
||||
.Nm
|
||||
.Ic mode
|
||||
.Ar device
|
||||
.Op Ar mode
|
||||
.Nm
|
||||
.Ic info
|
||||
.Ar channel
|
||||
@ -94,7 +95,7 @@ The
|
||||
.Ar channel
|
||||
argument is the ATA channel device (e.g., ata0) on which to operate.
|
||||
The following commands are supported:
|
||||
.Bl -tag -width "rebuild"
|
||||
.Bl -tag -width ".Ic addspare"
|
||||
.It Ic attach
|
||||
Attach an ATA
|
||||
.Ar channel .
|
||||
@ -162,9 +163,13 @@ Rebuild a RAID1 array on a RAID capable ATA controller.
|
||||
.It Ic status
|
||||
Get the status of an ATA RAID.
|
||||
.It Ic mode
|
||||
Without the mode argument, the current transfer modes of the
|
||||
Without the
|
||||
.Ar mode
|
||||
argument, the current transfer mode of the
|
||||
device are printed.
|
||||
If the mode argument is given, the ATA driver
|
||||
If the
|
||||
.Ar mode
|
||||
argument is given, the ATA driver
|
||||
is asked to change the transfer mode to the one given.
|
||||
The ATA driver
|
||||
will reject modes that are not supported by the hardware.
|
||||
@ -190,13 +195,12 @@ and
|
||||
.Cm UDMA6
|
||||
(alias
|
||||
.Cm UDMA133 ) .
|
||||
The device name and manufacture/version strings are shown.
|
||||
.It Ic cap
|
||||
Show detailed info about the device on
|
||||
.Ar device .
|
||||
.It Ic spindown
|
||||
Set or report timeout after which the
|
||||
.Ar device
|
||||
.Ar device
|
||||
will be spun down.
|
||||
To arm the timeout the device needs at least one more request after
|
||||
setting the timeout.
|
||||
@ -205,6 +209,7 @@ No further actions are needed in this case.
|
||||
.It Ic info
|
||||
Show info about the attached devices on the
|
||||
.Ar channel .
|
||||
The device name and manufacture/version strings are shown.
|
||||
.It Ic list
|
||||
Show info about all attached devices on all active controllers.
|
||||
.El
|
||||
@ -312,7 +317,7 @@ If the system has a pure software array and is not using a "real" ATA
|
||||
RAID controller, then shut the system down, make sure that the disk
|
||||
that was still working is moved to the bootable position (channel 0
|
||||
or whatever the BIOS allows the system to boot from) and the blank disk
|
||||
is placed in the secondary position, then boot the system into
|
||||
is placed in the secondary position, then boot the system into
|
||||
single-user mode and issue the command:
|
||||
.Pp
|
||||
.Dl "atacontrol addspare ar0 ad6"
|
||||
|
Loading…
Reference in New Issue
Block a user