mirror of
https://git.hardenedbsd.org/hardenedbsd/HardenedBSD.git
synced 2024-11-20 10:16:34 +01:00
197 lines
6.8 KiB
Plaintext
197 lines
6.8 KiB
Plaintext
.TH CONS 4P "9 December 1988"
|
|
.ds ]W Wisconsin ARGO 1.0
|
|
.UC 4
|
|
.SH NAME
|
|
CONS \- Connection Oriented Network Service
|
|
.SH SYNOPSIS
|
|
For use as a network service (CONS):
|
|
.nf
|
|
.sp
|
|
\fB#include <sys/socket.h>\fR
|
|
\fB#include <sys/mbuf.h>\fR
|
|
\fB#include <netargo/iso.h>\fR
|
|
\fB#include <netargo/cons.h>\fR
|
|
\fB#include <netargo/iso_errno.h>\fR
|
|
.sp
|
|
\fBint cons_output(isop, m, len, isdatagram)\fR
|
|
.sp
|
|
or for use as a subnetwork service (COSNS):
|
|
.sp
|
|
\fB#include <sys/socket.h>\fR
|
|
\fB#include <sys/mbuf.h>\fR
|
|
\fB#include <netargo/iso.h>\fR
|
|
\fB#include <net/if.h>\fR
|
|
\fB#include <netargo/cons.h>\fR
|
|
\fB#include <netargo/iso_errno.h>\fR
|
|
.sp
|
|
\fBint cosns_output(ifp, m, dst)
|
|
.fi
|
|
.SH DESCRIPTION
|
|
.PP
|
|
The Connection Oriented Network Service (CONS) implemented for the AOS R2
|
|
at the University of Wisconsin - Madison
|
|
supports transport protocols, acting as a network service,
|
|
and it also supports other network protocols, acting as a subnetwork
|
|
service or link-layer service.
|
|
Several software modules are combined to provide these services.
|
|
.TP 10
|
|
X.25
|
|
The CCITT X.25 packet layer and link layer protocols run on
|
|
a coprocessor (the EICON Network Adapter), which serves as a DTE.
|
|
.TP 10
|
|
Ecn driver
|
|
A device driver manages the interaction between
|
|
the coprocessor and the PC/RT.
|
|
.TP 10
|
|
CONS "glue"
|
|
A software module implements portions of the OSI CONS (ISO 8878),
|
|
which describes a way to use the X.25 protocols to support the
|
|
OSI connection-oriented network service.
|
|
.PP
|
|
The OSI CONS contains several "service elements"
|
|
that ARGO does not use or support.
|
|
Expedited data,
|
|
quality of service maintenance,
|
|
call collision resolution,
|
|
permanent virtual circuits,
|
|
user data on connect and release,
|
|
user-level acknowledgement
|
|
("receipt confirmation" in CCITT/ISO argot), and reset/resynchronize
|
|
are not supported.
|
|
Several of the service primitives for connection establishment
|
|
and release are not supported, and
|
|
numerous parameters to other primitives specified in the OSI CONS
|
|
are not supported.
|
|
The CONS glue does provide all the support necessary to run
|
|
ISO transport classes 0 and 4 over X.25, and ISO CLNP (also called
|
|
ISO IP) over X.25.
|
|
The subnetwork dependent convergence functions implemented in the glue
|
|
permit interoperability with
|
|
OSINET and EAN at this writing.
|
|
Interoperability with other networks will be established in the future.
|
|
.PP
|
|
The coprocessor that implements the X.25 link and packet layers
|
|
is the Eicon Technologies Access/X.25 Stand-Alone Network Adaper
|
|
(see \fIecn(4)\fR).
|
|
.PP
|
|
The glue module provides two interfaces to higher layers:
|
|
a "subnetwork service" (COSNS) used by network layer protocols, which
|
|
has a typical BSD kernel device driver interface
|
|
and
|
|
a "network service" (CONS) used by transport protocols, which has
|
|
a procedure call interface similar to that of IP and CLNP.
|
|
.PP
|
|
The network service is reliable and sequenced but does not
|
|
provide a graceful close service; it provides only an abort service.
|
|
.PP
|
|
The subnetwork service is neither reliable nor sequenced.
|
|
The subnetwork service implemented by the glue hides the
|
|
connection-oriented aspects of the protocols; nevertheless,
|
|
we call it the "connection-oriented subnetwork service" (COSNS)
|
|
here, for lack of a better name.
|
|
.SS "LIBRARIES
|
|
No libraries are needed to use the CONS, however,
|
|
the numerous error values returned by X.25 cannot be accommodated
|
|
by the standard \fIperror()\fR in the C library.
|
|
The ISO library
|
|
.nf
|
|
.sp
|
|
.in +5
|
|
\fC/usr/argo/lib/libisodir.a\fR
|
|
.in -5
|
|
.sp
|
|
.fi
|
|
provides an expanded perror() to handle the additional error return codes.
|
|
.SS "ERROR VALUES
|
|
.PP
|
|
The error codes returned by the CONS are taken from
|
|
the diagnostic code of the X.25 level 3 packets, as
|
|
descibed in figure 14-B of ISO 8208 (the ISO standard which
|
|
is equivalent to CCITT X.25).
|
|
The actual error value returned in
|
|
\fIerrno\fR
|
|
is the X.25 diagnostic code in the lower 10 bits
|
|
logically "or"ed with the hexadecimal value 0x8400 (bits
|
|
10 and 15 set, counting from zero at the the least significant bit).
|
|
The error values can be found in
|
|
the file
|
|
.nf
|
|
.in +5
|
|
.sp
|
|
\fC<netargo/iso_errno.h>\fR
|
|
.sp
|
|
.in -5
|
|
.fi
|
|
.SS "PROTOCOL IDENTIFICATION
|
|
.PP
|
|
The purpose of this section is to describe how incoming packets
|
|
are forwarded from the glue to the various higher
|
|
layers (ISO transport, CLNP), how
|
|
routes are chosen from the higher layers to the glue, and
|
|
how NSAP-addresses are related to all this.
|
|
.SS Outgoing path:
|
|
The ARGO transport entity routes packets either to
|
|
the CONS glue, to the CLNP module, or to the DARPA Internet IP
|
|
module, based on the value of the network service parameter
|
|
given to the transport layer by the user.
|
|
The \fInetserv\fR property of records in the ARGO
|
|
directory service database
|
|
can be used to determine the network service to be used by the
|
|
transport layer. See also \fIisodir(5)\fR and \fIisodir(3)\fR.
|
|
.PP
|
|
The connectionless network layer entity routes packets to the
|
|
COSNS based on the routing table entries in the connectionless network layer.
|
|
This means that any type of NSAP-address supported by the kernel
|
|
may be used with a CLNP packet
|
|
that is routed over X.25.
|
|
.PP
|
|
When the glue creates an X.25 Call Request packet, it
|
|
places an X.121 address (DTE address)
|
|
in both the Calling and Called DTE address fields.
|
|
The X.121 addresses are extracted from the \fISNPA cache\fR,
|
|
a table that maps NSAP-addresses to SNPA-addresses, and
|
|
is maintained by the ES-IS protocol module of the OSI network layer.
|
|
In addition to placing a DTE address in the X.25 packet,
|
|
the "glue" may
|
|
uses the 1984 Called Address Extension facility to convey the
|
|
NSAP-addresses.
|
|
Whether or not this is done depends on the compile-time option -DX25_1984.
|
|
.SS Incoming path:
|
|
The X.25 Call Request User Data field and the
|
|
1984 X.25 Address Extension Facility are used
|
|
to determing the incoming path through the network layer.
|
|
The NSAP addresses passed up along with the packet are taken from the
|
|
Address Extension facility, if present.
|
|
If the facility is absent, the glue creates two type-37 NSAP-addresses,
|
|
filling in the X.121 address from the called and
|
|
calling DTE-addresses on the Call Request packet, if present.
|
|
The glue then requests of the ES-IS module to add an entry to the
|
|
SNPA cache to associate the calling DTE address with its
|
|
derived NSAP-address.
|
|
These cache entries have a holding of 5 minutes, and get
|
|
refreshed as long as there is activity on the virtual circuit
|
|
resulting from the call request.
|
|
.PP
|
|
If a Call Request packet contains a protocol identifier
|
|
as described in ISO PTDR 9577, this protocol identifier is used
|
|
to route the packet to the higher layers.
|
|
If there is no protocol identifier, the higher layer is assumed to be ISO
|
|
transport.
|
|
.SH "BUGS
|
|
.PP
|
|
If an incoming X.25 Call Request contains no DTE-addresses and
|
|
no NSAP-addresses (in the Address Extension facility)
|
|
the kernel panics.
|
|
.SH "SEE ALSO
|
|
.PP
|
|
isodir(3),
|
|
ecn(4),
|
|
clnp(4),
|
|
tp(4),
|
|
isodir(5),
|
|
isoroute(8),
|
|
ifconfig(8),
|
|
netstat(1),
|
|
xstat(8),
|
|
"ARGO 1.0 Kernel Programmer's Manual"
|