mirror of
https://git.hardenedbsd.org/hardenedbsd/HardenedBSD.git
synced 2024-12-21 08:24:10 +01:00
130 lines
2.3 KiB
C
130 lines
2.3 KiB
C
/*
|
|
* lookup.c - Lookup IP address, HW address, netmask
|
|
*
|
|
* $FreeBSD$
|
|
*/
|
|
|
|
#include <sys/types.h>
|
|
#include <sys/socket.h>
|
|
|
|
#include <sys/time.h> /* for struct timeval in net/if.h */
|
|
#include <net/if.h>
|
|
#include <netinet/in.h>
|
|
|
|
#ifdef ETC_ETHERS
|
|
#include <net/ethernet.h>
|
|
extern int ether_hostton();
|
|
#endif
|
|
|
|
#include <netdb.h>
|
|
#include <syslog.h>
|
|
|
|
#ifndef USE_BFUNCS
|
|
#include <memory.h>
|
|
/* Yes, memcpy is OK here (no overlapped copies). */
|
|
#define bcopy(a,b,c) memcpy(b,a,c)
|
|
#endif
|
|
|
|
#include "bootp.h"
|
|
#include "lookup.h"
|
|
#include "report.h"
|
|
|
|
/*
|
|
* Lookup an Ethernet address and return it.
|
|
* Return NULL if addr not found.
|
|
*/
|
|
u_char *
|
|
lookup_hwa(hostname, htype)
|
|
char *hostname;
|
|
int htype;
|
|
{
|
|
switch (htype) {
|
|
|
|
/* XXX - How is this done on other systems? -gwr */
|
|
#ifdef ETC_ETHERS
|
|
case HTYPE_ETHERNET:
|
|
case HTYPE_IEEE802:
|
|
{
|
|
static struct ether_addr ea;
|
|
/* This does a lookup in /etc/ethers */
|
|
if (ether_hostton(hostname, &ea)) {
|
|
report(LOG_ERR, "no HW addr for host \"%s\"",
|
|
hostname);
|
|
return (u_char *) 0;
|
|
}
|
|
return (u_char *) & ea;
|
|
}
|
|
#endif /* ETC_ETHERS */
|
|
|
|
default:
|
|
report(LOG_ERR, "no lookup for HW addr type %d", htype);
|
|
} /* switch */
|
|
|
|
/* If the system can't do it, just return an error. */
|
|
return (u_char *) 0;
|
|
}
|
|
|
|
|
|
/*
|
|
* Lookup an IP address.
|
|
* Return non-zero on failure.
|
|
*/
|
|
int
|
|
lookup_ipa(hostname, result)
|
|
char *hostname;
|
|
u_int32 *result;
|
|
{
|
|
struct hostent *hp;
|
|
hp = gethostbyname(hostname);
|
|
if (!hp)
|
|
return -1;
|
|
bcopy(hp->h_addr, result, sizeof(*result));
|
|
return 0;
|
|
}
|
|
|
|
|
|
/*
|
|
* Lookup a netmask
|
|
* Return non-zero on failure.
|
|
*
|
|
* XXX - This is OK as a default, but to really make this automatic,
|
|
* we would need to get the subnet mask from the ether interface.
|
|
* If this is wrong, specify the correct value in the bootptab.
|
|
*/
|
|
int
|
|
lookup_netmask(addr, result)
|
|
u_int32 addr; /* both in network order */
|
|
u_int32 *result;
|
|
{
|
|
int32 m, a;
|
|
|
|
a = ntohl(addr);
|
|
m = 0;
|
|
|
|
if (IN_CLASSA(a))
|
|
m = IN_CLASSA_NET;
|
|
|
|
if (IN_CLASSB(a))
|
|
m = IN_CLASSB_NET;
|
|
|
|
if (IN_CLASSC(a))
|
|
m = IN_CLASSC_NET;
|
|
|
|
if (!m)
|
|
return -1;
|
|
*result = htonl(m);
|
|
return 0;
|
|
}
|
|
|
|
/*
|
|
* Local Variables:
|
|
* tab-width: 4
|
|
* c-indent-level: 4
|
|
* c-argdecl-indent: 4
|
|
* c-continued-statement-offset: 4
|
|
* c-continued-brace-offset: -4
|
|
* c-label-offset: -4
|
|
* c-brace-offset: 0
|
|
* End:
|
|
*/
|