mirror of
https://git.hardenedbsd.org/hardenedbsd/HardenedBSD.git
synced 2024-11-23 08:11:04 +01:00
537 lines
13 KiB
C
537 lines
13 KiB
C
/*-
|
|
* SPDX-License-Identifier: BSD-2-Clause-FreeBSD
|
|
*
|
|
* Copyright (c) 2004, 2007 Lukas Ertl
|
|
* All rights reserved.
|
|
*
|
|
* Redistribution and use in source and binary forms, with or without
|
|
* modification, are permitted provided that the following conditions
|
|
* are met:
|
|
* 1. Redistributions of source code must retain the above copyright
|
|
* notice, this list of conditions and the following disclaimer.
|
|
* 2. Redistributions in binary form must reproduce the above copyright
|
|
* notice, this list of conditions and the following disclaimer in the
|
|
* documentation and/or other materials provided with the distribution.
|
|
*
|
|
* THIS SOFTWARE IS PROVIDED BY THE AUTHOR AND CONTRIBUTORS ``AS IS'' AND
|
|
* ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
|
|
* IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
|
|
* ARE DISCLAIMED. IN NO EVENT SHALL THE AUTHOR OR CONTRIBUTORS BE LIABLE
|
|
* FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
|
|
* DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
|
|
* OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
|
|
* HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
|
|
* LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
|
|
* OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
|
|
* SUCH DAMAGE.
|
|
*/
|
|
|
|
#include <sys/cdefs.h>
|
|
__FBSDID("$FreeBSD$");
|
|
|
|
#include <sys/libkern.h>
|
|
#include <sys/malloc.h>
|
|
|
|
#include <geom/geom.h>
|
|
#include <geom/geom_dbg.h>
|
|
#include <geom/vinum/geom_vinum_var.h>
|
|
#include <geom/vinum/geom_vinum.h>
|
|
#include <geom/vinum/geom_vinum_share.h>
|
|
|
|
void
|
|
gv_setstate(struct g_geom *gp, struct gctl_req *req)
|
|
{
|
|
struct gv_softc *sc;
|
|
struct gv_sd *s;
|
|
struct gv_drive *d;
|
|
struct gv_volume *v;
|
|
struct gv_plex *p;
|
|
char *obj, *state;
|
|
int f, *flags, type;
|
|
|
|
f = 0;
|
|
obj = gctl_get_param(req, "object", NULL);
|
|
if (obj == NULL) {
|
|
gctl_error(req, "no object given");
|
|
return;
|
|
}
|
|
|
|
state = gctl_get_param(req, "state", NULL);
|
|
if (state == NULL) {
|
|
gctl_error(req, "no state given");
|
|
return;
|
|
}
|
|
|
|
flags = gctl_get_paraml(req, "flags", sizeof(*flags));
|
|
if (flags == NULL) {
|
|
gctl_error(req, "no flags given");
|
|
return;
|
|
}
|
|
|
|
if (*flags & GV_FLAG_F)
|
|
f = GV_SETSTATE_FORCE;
|
|
|
|
sc = gp->softc;
|
|
type = gv_object_type(sc, obj);
|
|
switch (type) {
|
|
case GV_TYPE_VOL:
|
|
if (gv_volstatei(state) < 0) {
|
|
gctl_error(req, "invalid volume state '%s'", state);
|
|
break;
|
|
}
|
|
v = gv_find_vol(sc, obj);
|
|
gv_post_event(sc, GV_EVENT_SET_VOL_STATE, v, NULL,
|
|
gv_volstatei(state), f);
|
|
break;
|
|
|
|
case GV_TYPE_PLEX:
|
|
if (gv_plexstatei(state) < 0) {
|
|
gctl_error(req, "invalid plex state '%s'", state);
|
|
break;
|
|
}
|
|
p = gv_find_plex(sc, obj);
|
|
gv_post_event(sc, GV_EVENT_SET_PLEX_STATE, p, NULL,
|
|
gv_plexstatei(state), f);
|
|
break;
|
|
|
|
case GV_TYPE_SD:
|
|
if (gv_sdstatei(state) < 0) {
|
|
gctl_error(req, "invalid subdisk state '%s'", state);
|
|
break;
|
|
}
|
|
s = gv_find_sd(sc, obj);
|
|
gv_post_event(sc, GV_EVENT_SET_SD_STATE, s, NULL,
|
|
gv_sdstatei(state), f);
|
|
break;
|
|
|
|
case GV_TYPE_DRIVE:
|
|
if (gv_drivestatei(state) < 0) {
|
|
gctl_error(req, "invalid drive state '%s'", state);
|
|
break;
|
|
}
|
|
d = gv_find_drive(sc, obj);
|
|
gv_post_event(sc, GV_EVENT_SET_DRIVE_STATE, d, NULL,
|
|
gv_drivestatei(state), f);
|
|
break;
|
|
|
|
default:
|
|
gctl_error(req, "unknown object '%s'", obj);
|
|
break;
|
|
}
|
|
}
|
|
|
|
/* Update drive state; return 0 if the state changes, otherwise error. */
|
|
int
|
|
gv_set_drive_state(struct gv_drive *d, int newstate, int flags)
|
|
{
|
|
struct gv_sd *s;
|
|
int oldstate;
|
|
|
|
KASSERT(d != NULL, ("gv_set_drive_state: NULL d"));
|
|
|
|
oldstate = d->state;
|
|
|
|
if (newstate == oldstate)
|
|
return (0);
|
|
|
|
/* We allow to take down an open drive only with force. */
|
|
if ((newstate == GV_DRIVE_DOWN) && gv_consumer_is_open(d->consumer) &&
|
|
(!(flags & GV_SETSTATE_FORCE)))
|
|
return (GV_ERR_ISBUSY);
|
|
|
|
d->state = newstate;
|
|
|
|
if (d->state != oldstate) {
|
|
LIST_FOREACH(s, &d->subdisks, from_drive)
|
|
gv_update_sd_state(s);
|
|
}
|
|
|
|
/* Save the config back to disk. */
|
|
if (flags & GV_SETSTATE_CONFIG)
|
|
gv_save_config(d->vinumconf);
|
|
|
|
return (0);
|
|
}
|
|
|
|
int
|
|
gv_set_sd_state(struct gv_sd *s, int newstate, int flags)
|
|
{
|
|
struct gv_drive *d;
|
|
struct gv_plex *p;
|
|
int oldstate, status;
|
|
|
|
KASSERT(s != NULL, ("gv_set_sd_state: NULL s"));
|
|
|
|
oldstate = s->state;
|
|
|
|
/* We are optimistic and assume it will work. */
|
|
status = 0;
|
|
|
|
if (newstate == oldstate)
|
|
return (0);
|
|
|
|
switch (newstate) {
|
|
case GV_SD_DOWN:
|
|
/*
|
|
* If we're attached to a plex, we won't go down without use of
|
|
* force.
|
|
*/
|
|
if ((s->plex_sc != NULL) && !(flags & GV_SETSTATE_FORCE))
|
|
return (GV_ERR_ISATTACHED);
|
|
break;
|
|
|
|
case GV_SD_REVIVING:
|
|
case GV_SD_INITIALIZING:
|
|
/*
|
|
* Only do this if we're forced, since it usually is done
|
|
* internally, and then we do use the force flag.
|
|
*/
|
|
if (!(flags & GV_SETSTATE_FORCE))
|
|
return (GV_ERR_SETSTATE);
|
|
break;
|
|
|
|
case GV_SD_UP:
|
|
/* We can't bring the subdisk up if our drive is dead. */
|
|
d = s->drive_sc;
|
|
if ((d == NULL) || (d->state != GV_DRIVE_UP))
|
|
return (GV_ERR_SETSTATE);
|
|
|
|
/* Check from where we want to be brought up. */
|
|
switch (s->state) {
|
|
case GV_SD_REVIVING:
|
|
case GV_SD_INITIALIZING:
|
|
/*
|
|
* The subdisk was initializing. We allow it to be
|
|
* brought up.
|
|
*/
|
|
break;
|
|
|
|
case GV_SD_DOWN:
|
|
/*
|
|
* The subdisk is currently down. We allow it to be
|
|
* brought up if it is not attached to a plex.
|
|
*/
|
|
p = s->plex_sc;
|
|
if (p == NULL)
|
|
break;
|
|
|
|
/*
|
|
* If this subdisk is attached to a plex, we allow it
|
|
* to be brought up if the plex if it's not a RAID5
|
|
* plex, otherwise it's made 'stale'.
|
|
*/
|
|
|
|
if (p->org != GV_PLEX_RAID5)
|
|
break;
|
|
else if (s->flags & GV_SD_CANGOUP) {
|
|
s->flags &= ~GV_SD_CANGOUP;
|
|
break;
|
|
} else if (flags & GV_SETSTATE_FORCE)
|
|
break;
|
|
else
|
|
s->state = GV_SD_STALE;
|
|
|
|
status = GV_ERR_SETSTATE;
|
|
break;
|
|
|
|
case GV_SD_STALE:
|
|
/*
|
|
* A stale subdisk can be brought up only if it's part
|
|
* of a concat or striped plex that's the only one in a
|
|
* volume, or if the subdisk isn't attached to a plex.
|
|
* Otherwise it needs to be revived or initialized
|
|
* first.
|
|
*/
|
|
p = s->plex_sc;
|
|
if (p == NULL || flags & GV_SETSTATE_FORCE)
|
|
break;
|
|
|
|
if ((p->org != GV_PLEX_RAID5 &&
|
|
p->vol_sc->plexcount == 1) ||
|
|
(p->flags & GV_PLEX_SYNCING &&
|
|
p->synced > 0 &&
|
|
p->org == GV_PLEX_RAID5))
|
|
break;
|
|
else
|
|
return (GV_ERR_SETSTATE);
|
|
|
|
default:
|
|
return (GV_ERR_INVSTATE);
|
|
}
|
|
break;
|
|
|
|
/* Other state transitions are only possible with force. */
|
|
default:
|
|
if (!(flags & GV_SETSTATE_FORCE))
|
|
return (GV_ERR_SETSTATE);
|
|
}
|
|
|
|
/* We can change the state and do it. */
|
|
if (status == 0)
|
|
s->state = newstate;
|
|
|
|
/* Update our plex, if we're attached to one. */
|
|
if (s->plex_sc != NULL)
|
|
gv_update_plex_state(s->plex_sc);
|
|
|
|
/* Save the config back to disk. */
|
|
if (flags & GV_SETSTATE_CONFIG)
|
|
gv_save_config(s->vinumconf);
|
|
|
|
return (status);
|
|
}
|
|
|
|
int
|
|
gv_set_plex_state(struct gv_plex *p, int newstate, int flags)
|
|
{
|
|
struct gv_volume *v;
|
|
int oldstate, plexdown;
|
|
|
|
KASSERT(p != NULL, ("gv_set_plex_state: NULL p"));
|
|
|
|
oldstate = p->state;
|
|
v = p->vol_sc;
|
|
plexdown = 0;
|
|
|
|
if (newstate == oldstate)
|
|
return (0);
|
|
|
|
switch (newstate) {
|
|
case GV_PLEX_UP:
|
|
/* Let update_plex handle if the plex can come up */
|
|
gv_update_plex_state(p);
|
|
if (p->state != GV_PLEX_UP && !(flags & GV_SETSTATE_FORCE))
|
|
return (GV_ERR_SETSTATE);
|
|
p->state = newstate;
|
|
break;
|
|
case GV_PLEX_DOWN:
|
|
/*
|
|
* Set state to GV_PLEX_DOWN only if no-one is using the plex,
|
|
* or if the state is forced.
|
|
*/
|
|
if (v != NULL) {
|
|
/* If the only one up, force is needed. */
|
|
plexdown = gv_plexdown(v);
|
|
if ((v->plexcount == 1 ||
|
|
(v->plexcount - plexdown == 1)) &&
|
|
((flags & GV_SETSTATE_FORCE) == 0))
|
|
return (GV_ERR_SETSTATE);
|
|
}
|
|
p->state = newstate;
|
|
break;
|
|
case GV_PLEX_DEGRADED:
|
|
/* Only used internally, so we have to be forced. */
|
|
if (flags & GV_SETSTATE_FORCE)
|
|
p->state = newstate;
|
|
break;
|
|
}
|
|
|
|
/* Update our volume if we have one. */
|
|
if (v != NULL)
|
|
gv_update_vol_state(v);
|
|
|
|
/* Save config. */
|
|
if (flags & GV_SETSTATE_CONFIG)
|
|
gv_save_config(p->vinumconf);
|
|
return (0);
|
|
}
|
|
|
|
int
|
|
gv_set_vol_state(struct gv_volume *v, int newstate, int flags)
|
|
{
|
|
int oldstate;
|
|
|
|
KASSERT(v != NULL, ("gv_set_vol_state: NULL v"));
|
|
|
|
oldstate = v->state;
|
|
|
|
if (newstate == oldstate)
|
|
return (0);
|
|
|
|
switch (newstate) {
|
|
case GV_VOL_UP:
|
|
/* Let update handle if the volume can come up. */
|
|
gv_update_vol_state(v);
|
|
if (v->state != GV_VOL_UP && !(flags & GV_SETSTATE_FORCE))
|
|
return (GV_ERR_SETSTATE);
|
|
v->state = newstate;
|
|
break;
|
|
case GV_VOL_DOWN:
|
|
/*
|
|
* Set state to GV_VOL_DOWN only if no-one is using the volume,
|
|
* or if the state should be forced.
|
|
*/
|
|
if (!gv_provider_is_open(v->provider) &&
|
|
!(flags & GV_SETSTATE_FORCE))
|
|
return (GV_ERR_ISBUSY);
|
|
v->state = newstate;
|
|
break;
|
|
}
|
|
/* Save config */
|
|
if (flags & GV_SETSTATE_CONFIG)
|
|
gv_save_config(v->vinumconf);
|
|
return (0);
|
|
}
|
|
|
|
/* Update the state of a subdisk based on its environment. */
|
|
void
|
|
gv_update_sd_state(struct gv_sd *s)
|
|
{
|
|
struct gv_drive *d;
|
|
int oldstate;
|
|
|
|
KASSERT(s != NULL, ("gv_update_sd_state: NULL s"));
|
|
d = s->drive_sc;
|
|
KASSERT(d != NULL, ("gv_update_sd_state: NULL d"));
|
|
|
|
oldstate = s->state;
|
|
|
|
/* If our drive isn't up we cannot be up either. */
|
|
if (d->state != GV_DRIVE_UP) {
|
|
s->state = GV_SD_DOWN;
|
|
/* If this subdisk was just created, we assume it is good.*/
|
|
} else if (s->flags & GV_SD_NEWBORN) {
|
|
s->state = GV_SD_UP;
|
|
s->flags &= ~GV_SD_NEWBORN;
|
|
} else if (s->state != GV_SD_UP) {
|
|
if (s->flags & GV_SD_CANGOUP) {
|
|
s->state = GV_SD_UP;
|
|
s->flags &= ~GV_SD_CANGOUP;
|
|
} else
|
|
s->state = GV_SD_STALE;
|
|
} else
|
|
s->state = GV_SD_UP;
|
|
|
|
if (s->state != oldstate)
|
|
G_VINUM_DEBUG(1, "subdisk %s state change: %s -> %s", s->name,
|
|
gv_sdstate(oldstate), gv_sdstate(s->state));
|
|
|
|
/* Update the plex, if we have one. */
|
|
if (s->plex_sc != NULL)
|
|
gv_update_plex_state(s->plex_sc);
|
|
}
|
|
|
|
/* Update the state of a plex based on its environment. */
|
|
void
|
|
gv_update_plex_state(struct gv_plex *p)
|
|
{
|
|
struct gv_sd *s;
|
|
int sdstates;
|
|
int oldstate;
|
|
|
|
KASSERT(p != NULL, ("gv_update_plex_state: NULL p"));
|
|
|
|
oldstate = p->state;
|
|
|
|
/* First, check the state of our subdisks. */
|
|
sdstates = gv_sdstatemap(p);
|
|
|
|
/* If all subdisks are up, our plex can be up, too. */
|
|
if (sdstates == GV_SD_UPSTATE)
|
|
p->state = GV_PLEX_UP;
|
|
|
|
/* One or more of our subdisks are down. */
|
|
else if (sdstates & GV_SD_DOWNSTATE) {
|
|
/* A RAID5 plex can handle one dead subdisk. */
|
|
if ((p->org == GV_PLEX_RAID5) && (p->sddown == 1))
|
|
p->state = GV_PLEX_DEGRADED;
|
|
else
|
|
p->state = GV_PLEX_DOWN;
|
|
|
|
/* Some of our subdisks are initializing. */
|
|
} else if (sdstates & GV_SD_INITSTATE) {
|
|
if (p->flags & GV_PLEX_SYNCING ||
|
|
p->flags & GV_PLEX_REBUILDING)
|
|
p->state = GV_PLEX_DEGRADED;
|
|
else
|
|
p->state = GV_PLEX_DOWN;
|
|
} else
|
|
p->state = GV_PLEX_DOWN;
|
|
|
|
if (p->state == GV_PLEX_UP) {
|
|
LIST_FOREACH(s, &p->subdisks, in_plex) {
|
|
if (s->flags & GV_SD_GROW) {
|
|
p->state = GV_PLEX_GROWABLE;
|
|
break;
|
|
}
|
|
}
|
|
}
|
|
|
|
if (p->state != oldstate)
|
|
G_VINUM_DEBUG(1, "plex %s state change: %s -> %s", p->name,
|
|
gv_plexstate(oldstate), gv_plexstate(p->state));
|
|
|
|
/* Update our volume, if we have one. */
|
|
if (p->vol_sc != NULL)
|
|
gv_update_vol_state(p->vol_sc);
|
|
}
|
|
|
|
/* Update the volume state based on its plexes. */
|
|
void
|
|
gv_update_vol_state(struct gv_volume *v)
|
|
{
|
|
struct gv_plex *p;
|
|
|
|
KASSERT(v != NULL, ("gv_update_vol_state: NULL v"));
|
|
|
|
/* The volume can't be up without plexes. */
|
|
if (v->plexcount == 0) {
|
|
v->state = GV_VOL_DOWN;
|
|
return;
|
|
}
|
|
|
|
LIST_FOREACH(p, &v->plexes, in_volume) {
|
|
/* One of our plexes is accessible, and so are we. */
|
|
if (p->state > GV_PLEX_DEGRADED) {
|
|
v->state = GV_VOL_UP;
|
|
return;
|
|
|
|
/* We can handle a RAID5 plex with one dead subdisk as well. */
|
|
} else if ((p->org == GV_PLEX_RAID5) &&
|
|
(p->state == GV_PLEX_DEGRADED)) {
|
|
v->state = GV_VOL_UP;
|
|
return;
|
|
}
|
|
}
|
|
|
|
/* Not one of our plexes is up, so we can't be either. */
|
|
v->state = GV_VOL_DOWN;
|
|
}
|
|
|
|
/* Return a state map for the subdisks of a plex. */
|
|
int
|
|
gv_sdstatemap(struct gv_plex *p)
|
|
{
|
|
struct gv_sd *s;
|
|
int statemap;
|
|
|
|
KASSERT(p != NULL, ("gv_sdstatemap: NULL p"));
|
|
|
|
statemap = 0;
|
|
p->sddown = 0; /* No subdisks down yet. */
|
|
|
|
LIST_FOREACH(s, &p->subdisks, in_plex) {
|
|
switch (s->state) {
|
|
case GV_SD_DOWN:
|
|
case GV_SD_STALE:
|
|
statemap |= GV_SD_DOWNSTATE;
|
|
p->sddown++; /* Another unusable subdisk. */
|
|
break;
|
|
|
|
case GV_SD_UP:
|
|
statemap |= GV_SD_UPSTATE;
|
|
break;
|
|
|
|
case GV_SD_INITIALIZING:
|
|
statemap |= GV_SD_INITSTATE;
|
|
break;
|
|
|
|
case GV_SD_REVIVING:
|
|
statemap |= GV_SD_INITSTATE;
|
|
p->sddown++; /* XXX: Another unusable subdisk? */
|
|
break;
|
|
}
|
|
}
|
|
return (statemap);
|
|
}
|