HardenedBSD/sys/arm/broadcom/bcm2835/bcm2835_vcbus.h
Pedro F. Giffuni af3dc4a7ca sys/arm: further adoption of SPDX licensing ID tags.
Mainly focus on files that use BSD 2-Clause license, however the tool I
was using misidentified many licenses so this was mostly a manual - error
prone - task.

The Software Package Data Exchange (SPDX) group provides a specification
to make it easier for automated tools to detect and summarize well known
opensource licenses. We are gradually adopting the specification, noting
that the tags are considered only advisory and do not, in any way,
superceed or replace the license texts.
2017-11-27 15:04:10 +00:00

82 lines
2.8 KiB
C

/*-
* SPDX-License-Identifier: BSD-2-Clause-FreeBSD
*
* Copyright (c) 2012 Oleksandr Tymoshenko <gonzo@freebsd.org>
* All rights reserved.
*
* Redistribution and use in source and binary forms, with or without
* modification, are permitted provided that the following conditions
* are met:
* 1. Redistributions of source code must retain the above copyright
* notice, this list of conditions and the following disclaimer.
* 2. Redistributions in binary form must reproduce the above copyright
* notice, this list of conditions and the following disclaimer in the
* documentation and/or other materials provided with the distribution.
*
* THIS SOFTWARE IS PROVIDED BY THE AUTHOR AND CONTRIBUTORS ``AS IS'' AND
* ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
* IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
* ARE DISCLAIMED. IN NO EVENT SHALL THE AUTHOR OR CONTRIBUTORS BE LIABLE
* FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
* DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
* OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
* HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
* LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
* OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
* SUCH DAMAGE.
*
* $FreeBSD$
*/
/*
* Defines for converting physical address to VideoCore bus address and back
*/
#ifndef _BCM2835_VCBUS_H_
#define _BCM2835_VCBUS_H_
/*
* ARM64 define its SOC options in opt_soc.h
*/
#if defined(__aarch64__)
#include "opt_soc.h"
#endif
#define BCM2835_VCBUS_SDRAM_CACHED 0x40000000
#define BCM2835_VCBUS_IO_BASE 0x7E000000
#define BCM2835_VCBUS_SDRAM_UNCACHED 0xC0000000
#if defined(SOC_BCM2835)
#define BCM2835_ARM_IO_BASE 0x20000000
#define BCM2835_VCBUS_SDRAM_BASE BCM2835_VCBUS_SDRAM_CACHED
#else
#define BCM2835_ARM_IO_BASE 0x3f000000
#define BCM2835_VCBUS_SDRAM_BASE BCM2835_VCBUS_SDRAM_UNCACHED
#endif
#define BCM2835_ARM_IO_SIZE 0x01000000
/*
* Convert physical address to VC bus address. Should be used
* when submitting address over mailbox interface
*/
#define PHYS_TO_VCBUS(pa) ((pa) + BCM2835_VCBUS_SDRAM_BASE)
/* Check whether pa bellong top IO window */
#define BCM2835_ARM_IS_IO(pa) (((pa) >= BCM2835_ARM_IO_BASE) && \
((pa) < BCM2835_ARM_IO_BASE + BCM2835_ARM_IO_SIZE))
/*
* Convert physical address in IO space to VC bus address.
*/
#define IO_TO_VCBUS(pa) ((pa - BCM2835_ARM_IO_BASE) + \
BCM2835_VCBUS_IO_BASE)
/*
* Convert address from VC bus space to physical. Should be used
* when address is returned by VC over mailbox interface. e.g.
* framebuffer base
*/
#define VCBUS_TO_PHYS(vca) ((vca) & ~(BCM2835_VCBUS_SDRAM_BASE))
#endif /* _BCM2835_VCBUS_H_ */